Transaortic transcatheter aortic valve implantation using SAPIEN XT or SAPIEN 3 valves in the ROUTE registry

Affiliation auteurs!!!! Error affiliation !!!!
TitreTransaortic transcatheter aortic valve implantation using SAPIEN XT or SAPIEN 3 valves in the ROUTE registry
Type de publicationJournal Article
Year of Publication2017
AuteursRomano M, Frank D, Cocchieri R, Jagielak D, Bonaros N, Aiello M, Lapeze J, Laine M, Chocron S, Muir D, Eichinger W, Thielmann M, Labrousse L, Rein KArne, Verhoye J-P, Gerosa G, Baumbach H, Deutsch C, Bramlage P, Thoenes M, Bapat V
JournalINTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY
Volume25
Pagination757-764
Date PublishedNOV
Type of ArticleArticle
ISSN1569-9293
Mots-clésBalloon expandable, Mortality, transaortic, transcatheter aortic valve implantation
Résumé

OBJECTIVES: Transaortic (TAo) access for transcatheter aortic valve implantation (TAVI) is an alternative to the conventional transfemoral or transapical routes. Data comparing the characteristics and outcomes of TAo-TAVI using the SAPIEN XT and SAPIEN 3 heart valves are scarce. The objective of the current analysis was to provide such information. METHODS: ROUTE is an international, prospective, observational registry. Patients with severe calcific aortic stenosis scheduled for TAo-TAVI with an Edwards SAPIEN XT or a SAPIEN 3 heart valve were consecutively enrolled at 22 centres across Europe between February 2013 and February 2015. Periprocedural, in-hospital and 30-day complication rates were assessed. RESULTS: Of the 301 patients included, 126 (41.9%) received a SAPIEN 3 and 175 (58.1%) a SAPIEN XT. The SAPIEN 3 was associated with shorter procedure time (101 +/- 35 vs 111 +/- 40 min; P = 0.031) and a lower quantity of contrast agent used (87 +/- 43 vs 112 +/- 50 ml; P < 0.001). Balloon dilation was performed less often before (68.0% vs 78.3%; P = 0.045) and after implantation (13.6% vs 30.1%; P = 0.001). No statistically significant differences between the valve types were documented for overall (4.1% SAPIEN 3 vs 7.6% SAPIEN XT; P = 0.21), TAVI-related (0.8% vs 4.7%; P = 0.084) and cardiovascular mortality (2.4% vs 5.9%; P = 0.158). Major vascular complications were less frequent (0.8% vs 5.3%; P = 0.049), and there was a lower rate of moderate-to-severe paravalvular regurgitation (0.8% vs 5.1%; P = 0.050) in the SAPIEN 3 group. CONCLUSIONS: Both the SAPIEN XT and SAPIEN 3 were safely implanted via the TAo route, though the SAPIEN 3 may be associated with a higher procedural success rate and improved prognosis.

DOI10.1093/icvts/ivx159