Impact of cord blood banking technologies on clinical outcome: a Eurocord/Cord Blood Committee (CTIWP), European Society for Blood and Marrow Transplantation and NetCord retrospective analysis

Affiliation auteurs!!!! Error affiliation !!!!
TitreImpact of cord blood banking technologies on clinical outcome: a Eurocord/Cord Blood Committee (CTIWP), European Society for Blood and Marrow Transplantation and NetCord retrospective analysis
Type de publicationJournal Article
Year of Publication2016
AuteursSaccardi R, Tucunduva L, Ruggeri A, Ionescu I, Koegler G, Querol S, Grazzini G, Lecchi L, Costa ANanni, Navarrete C, Pouthiers F, Larghero J, Regan D, Freeman T, Bittencourt H, Kenzey C, Labopin M, Baudoux E, Rocha V, Gluckman E
JournalTRANSFUSION
Volume56
Pagination2021-2029
Date PublishedAUG
Type of ArticleArticle
ISSN0041-1132
Résumé

BACKGROUNDTechniques for banking cord blood units (CBUs) as source for hematopoietic stem cell transplantation have been developed over the past 20 years, aimed to improve laboratory efficiency without altering the biologic properties of the graft. A large-scale, registry-based assessment of the impact of the banking variables on the clinical outcome is currently missing. STUDY DESIGN AND METHODSA total of 677 single cord blood transplants (CBTs) carried out for acute leukemia in complete remission in centers affiliated with the European Society for Blood and Marrow Transplantation were selected. An extensive set of data concerning CBU banking were collected and correlations with clinical outcome were assessed. Clinical endpoints were transplant-related mortality, engraftment, and graft-versus-host disease (GVHD). RESULTSThe median time between collection and CBT was 4.1 years (range, 0.2-16.3 years). Volume reduction (VR) of CBUs before freezing was performed in 59.2% of available reports; in half of these the frozen volume was less than 30 mL. Cumulative incidences of neutrophil engraftment on Day 60, 100-day acute GVHD (II-IV), and 4-year chronic GVHD were 87, 29, and 212%. The cumulative incidence of nonrelapse mortality (NRM) at 100 days and 4-year NRM were, respectively, 16 +/- 2 and 30 +/- 2%. Neither the variables related to banking procedures nor the interval between collection and CBT influenced the clinical outcome. CONCLUSIONThese findings indicate a satisfactory validation of the techniques associated with CBU VR across the banks. Cell viability assessment varied among the banks, suggesting that efforts to improve the standardization of CBU quality controls are needed.

DOI10.1111/trf.13661