Data-driven diagnosis of PEM fuel cell: A comparative study

Affiliation auteurs!!!! Error affiliation !!!!
TitreData-driven diagnosis of PEM fuel cell: A comparative study
Type de publicationJournal Article
Year of Publication2014
AuteursLi Z, Outbib R, Hissel D, Giurgea S
JournalCONTROL ENGINEERING PRACTICE
Volume28
Pagination1-12
Date PublishedJUL
Type of ArticleArticle
ISSN0967-0661
Mots-clésClassification, Fault diagnosis, feature extraction, PEMFC, water management
Résumé

This paper is dedicated to data-driven diagnosis for Polymer Electrolyte Membrane Fuel Cell (PEMFC). More precisely, it deals with water related faults (flooding and membrane drying) by using pattern classification methodologies. Firstly, a method based on physical considerations is defined to label the training data. Secondly, a feature extraction procedure is carried out to pick up the significant features from vectors constructed by individual cell voltages. Finally, a classification is adopted in the feature space to realize the fault diagnosis. Various feature extraction and classification methodologies are employed on a 20-cell PEMFC stack. The performances of these methodologies are compared. (C) 2014 Elsevier Ltd. All rights reserved.

DOI10.1016/j.conengprac.2014.02.019