Weld pool surface temperature measurement from polarization state of thermal emission

Affiliation auteurs!!!! Error affiliation !!!!
TitreWeld pool surface temperature measurement from polarization state of thermal emission
Type de publicationJournal Article
Year of Publication2016
AuteursConiglio N, Mathieu A, Aubreton O, Stolz C
JournalQUANTITATIVE INFRARED THERMOGRAPHY JOURNAL
Volume13
Pagination83-93
Date PublishedJAN 2
Type of ArticleArticle
ISSN1768-6733
Mots-clésgas tungsten arc, Polarimetry, Stokes imaging, weld pool temperature
Résumé

This paper presents a passive polarimetry method using a division of aperture optical device in order to measure the temperature distribution at the weld pool surface. Thermal emission from a hot liquid metal was investigated at a near-infrared wavelength corresponding to a blind spectral window of a helium plasma generated during gas tungsten arc welding process. The refractive index of liquid metal and the surface radiance are deduced from the polarisation state of thermal emissions. Based upon the knowledge of both characteristics, the temperature distribution can be calculated.

DOI10.1080/17686733.2015.1102475