Inter-turn fault detection in stator winding of PMSM using wavelet transform

Affiliation auteurs!!!! Error affiliation !!!!
TitreInter-turn fault detection in stator winding of PMSM using wavelet transform
Type de publicationConference Paper
Year of Publication2017
AuteursMoosavi S.S, Esmaili Q., Djerdir A., Y. Amirat A
Conference Name2017 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC)
PublisherIEEE; Alstom; Sonceboz; Femto st Sci & Technologies; FC Lab Res; IEEE VTS; Megevh; Univ Bourgogne Franche Comte; Univ Franche Comte; Univ Technologie Belfort Montbeliard; IUT Belfort Montbeliard; UFR STGI; Univ Technologie Belfort Montbeliard, Departement
Conference Location345 E 47TH ST, NEW YORK, NY 10017 USA
ISBN Number978-1-5386-1317-7
Mots-clésfault detection, Inter-turn short circuit, PMSM, wavelet transform (WT)
Résumé

the inter-turn short circuit fault is one of the most common faults in electrical machines. For safety reasons, reliability and maintenance, the fault needs to be detected and diagnosed as early as possible after its occurrence. This paper focuses on inter-turn short circuit fault detection in stator windings of a Permanent magnet synchronous motor (PMSM). A time frequency method has been used for analysis and data processing for detection of different levels of short circuit faults. Experimental data have been employed to validate the simulation results.