Double-modulation CPT cesium compact clock
Affiliation auteurs | !!!! Error affiliation !!!! |
Titre | Double-modulation CPT cesium compact clock |
Type de publication | Conference Paper |
Year of Publication | 2016 |
Auteurs | Yun P, Mejri S, Tricot F, Hafiz MAbdel, Boudot R, de Clercq E, Guerandel S |
Editor | Riehle F |
Conference Name | 8TH SYMPOSIUM ON FREQUENCY STANDARDS AND METROLOGY 2015 |
Publisher | Physikalisch Technische Bundesanstalt; Helmholtz Fonds e V; Natl Inst Standards & Technol; First TF; Observ Paris; Ctr Natl Rech Sci; Lab Natl Metrologie & Dessais; Deutsche Forschungsgemeinschaft |
Conference Location | DIRAC HOUSE, TEMPLE BACK, BRISTOL BS1 6BE, ENGLAND |
Résumé | Double-modulation coherent population trapping (CPT) is based on a synchronous modulation of Raman phase and laser polarization, which allows the atomic population to accumulate in a common dark state. The high contrast signal obtained on the clock transition with a relative compact and robust laser system is interesting as basis of a high performance microwave clock. Here we study the parameters of a double-modulation CPT Cs clock working in cw mode. The optimal polarization modulation frequency and cell temperature for maximum contrast of clock transition are investigated. The parameters of the detection are also studied. With the optimal parameters, we observe a CPT signal with contrast of 10% and linewidth of 492 Hz, which is well suited for implementing a cw atomic clock. |
DOI | 10.1088/1742-6596/723/1/012012 |