A lumped fluidic model of an anode chamber for fault tolerant strategy design

Affiliation auteurs!!!! Error affiliation !!!!
TitreA lumped fluidic model of an anode chamber for fault tolerant strategy design
Type de publicationJournal Article
Year of Publication2016
AuteursFukuhara S, Marx N, Ettihir K, Boulon L, Ait-Amirat Y, Becherif M
JournalINTERNATIONAL JOURNAL OF HYDROGEN ENERGY
Volume41
Pagination5037-5047
Date PublishedMAR 9
Type of ArticleArticle
ISSN0360-3199
Mots-clésCarbon corrosion, Exhaust gas management, Fault tolerant, Fuel cell, Model, PEM
Résumé

Water management in Proton Exchange Membrane (PEM) fuel cell systems is a critical point. This article will widely explain the importance of anode exhaust gas management for fuel cell and the issues of liquid water accumulation in the anodic compartment of a dead-ended anode fuel cell system. A OD model of the water behavior in the anode channels is introduced and an identification procedure of the water diffusion coefficient and a tunable parameter, using the least-square criteria, has been developed. The presented results show good correlation, allowing to extend the model to hydrogen and to validate it with experiments. This model will be useful to elaborate a fault tolerant strategy to mitigate the impact of liquid water accumulation into the anode chamber. Copyright (C) 2016, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.

DOI10.1016/j.ijhydene.2016.01.110